Carrier 48fc 15 ton.

Page 41: Rtu Open Controller (Factory Option) Completing Return Air Smoke Sensor Installation RTU Open Controller (Factory Option) Unscrew the two screws holding the Return Air Smoke For details on operating 48FC**04-07 units equipped with the Detector assembly. See Fig. 53, Step 1.

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Low Heat. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48FCDA04A2A30A0A0. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3. MFR:Carrier 48fc 10 Ton, Carrier Commercial Packaged Outdoor Units Melrose Park, IL, WeatherMaker® 48FC Single-Packaged Rooftop Units with EcoBlue™ Technology ... 2023-12-24; 2023-12-23; 2016-02-15; 2012-12-24; 2016-01-28; 2015-09-27; 2022-10-19; carrier 48fc 10 ton. RTU Curb Adapters Welded Curb Adapters Curbco. Carrier 48FC … Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions. 48FC units are single-packaged electric cooling, gas heating unit that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. Sizes 04-06 models use single-stage cooling capacity control. Size 07 models use two-stage cooling capacity control. FEATURES.

SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.The Performance heat pump, with two-stage compressor, lets you enjoy smooth, consistent comfort, quieter operation and improved air flow all year long. It's an extra-efficient heat pump system that also utilizes a multi-speed blower to help achieve enhanced summer dehumidification. Includes tin-plated copper coils for enhanced corrosion resistance.Puron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does ... Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. ... ton). Coupled with the improved dehumidification associated with

10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …

Overview. Performance series heat pumps offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The 25SPA5 boasts cooling efficiencies of up to 15.2 SEER2. And, like other Carrier heat pumps, it's designed to be Hybrid Heat® system compatible to help you save on heating costs in winter too. Page 41: Rtu Open Controller (Factory Option) Completing Return Air Smoke Sensor Installation RTU Open Controller (Factory Option) Unscrew the two screws holding the Return Air Smoke For details on operating 48FC**04-07 units equipped with the Detector assembly. See Fig. 53, Step 1. Carrier has introduced Weather Series Rooftop Units with EcoBlueTM Technology. One of EcoBlue's many innovative features is the exclusive beltless direct-drive vane axial fan that replaces traditional belt drive fans with a simpler, more compact design for improved performance and efficiency while decreasing maintenance and installation costs.Restore set-points for thermostat and humidistat (Y/N) _____. 2021 Carrier. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs …

Carrier West Training – HVAC Training

View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air conditioner pdf manual download. Also for: 50gc series, 48fc 04, 48fc 05,...

All WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners.With solutions from 10 through 500 tons, screw or scroll, Carrier air-cooled chillers are the best choice for your needs. With a wide range of air-cooled chiller scroll and screw types, capacities (10 to 500 tons) and sustainable refrigerant options, Carrier is a leader in the industry. Whether it be non-ozone depleting refrigerant, simple ...Features. Options. Physical Data. Documents. Performance Features. ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82% …Carrier 48FC Installation Instructions (2 pages) Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory Manual is suitable for 4 more products: 48 GC 48 HC 48 LC 48 TC10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …

CE - Carrier Enterprise S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time andCarrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR News04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerIEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw …

3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-1 VOLT GAS ELECTRIC RTU. ... 48FCEA04A2A3-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; BTU Input 90000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Vane Axial;

Carrier Enterprise Mid-Atlantic Technical Support Site1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).CarrierCarrier West Training – HVAC TrainingGAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and time periods set forth herein.Air Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 …24SPA636W003 24 = AC w/ R-410A / Product Series / Refrigerant S = Single Stage / Design Type P = Performance Series / Tier A = Initial / Major Series 6 = 16 SEER2 36 = 3 Ton / Cooling Capacity W = Standard SW AC / Region 0 = Standard / Feature 0 = Standard / Special Feature 3 = 208/230-1 / Voltage NOTE: Ratings are subject to change at any …Replacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480371-01 Printed in U.S.A. Form 48FC-16-01SI Rev. A Pg 1 7-22 Replaces: New. Understand the signal words DANGER, WARNING, CAUTION, and NOTE.

access it. Carrier r ooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters. Key features: Key features are: † Single cooling stage models are available from 6 to 10 ton. † 2-stage cooling stage models are available from 7.5 to 15 ton. † EERs up to 11.1 † IEERs up to 11.7 with single speed

Features. Options. Physical Data. Documents. Performance Features. ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82% …Carrier 48FC 5 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; 10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48fc-8-14-01si ; 48fcem 10t 208-230-3 ... Specifications. Brand ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 70 FAN PERFORMANCE (cont.) Table 57 – 48TC**16 3 PHASE 15 TON HORIZONTAL SUPPLY Available External Static Pressure ...NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Two-stage cooling capacity control on all models. SEER to 16.0. Gas efficiencies up to 82%. Cooling operating range up to 125 °F (52°C) and down to 35°F (2°C)Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES AND BENEFITS. Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor) Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480371-01 Printed in U.S.A. Form 48FC-16-01SI Rev. A Pg 1 7-22 Replaces: New. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C) Innovative …48FC 08-14 size units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air ... Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480371-01 Printed in U.S.A. Form 48FC-16-01SI Rev. A Pg 1 7-22 Replaces: New. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. Performance Features. 38AUQ Heat Pump EERs up to 11.0 and 3.5 COP. ASHRAE 90.1 Efficiency Compliant. Standard crankcase heater. Compressor vibration isolation. Low ambient temperature control. Unit performance certified in …

According to FEC filings, Donald Trump, the Republican nominee for president, raised $22 million last month. By clicking "TRY IT", I agree to receive newsletters and promotions fro...Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas HeatAir Conditioner Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 32 Table 15 — Quick Test, Unit Configuration and Switch Check QUICK NORMAL TEST DISPLAY STEP NO. 0 or 1 0 …els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies areInstagram:https://instagram. burke county landfillgotrax gxl v2 increase speedcraftsman rototiller 917de un da ga pow wow The price for a ton of coal varies greatly depending on what kind of coal it is. According to the U.S. Energy Information Administration, the average price for coal in 2012 was $39... columbus body works veterans parkwayaccidentally took 4000 mg metformin 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU 48TCEM08A2A5-0A0A0. ... Brand Carrier; BTU Input 224000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Centrifugal; Frame Size 56; Gas Stages 2-Stage; Heat Size Medium Gas Heat; LEER 12.7; Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup- little caesars pizza owensboro kentucky Field Convertible airflow (3−12.5 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 12.5 ton models require a simple supply air duct cover to field convert from factory vertical to horizontal. Provisions for thru−the−bottom power entry capability as standardDrawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. DXF/CAD templates are full scale 2D drawings of Carrier products. Layers are used to separate unit outlines, clearances, dimensions, and connections. Drawings are provided in AutoCAD® 1 DXF format (Drawing Interchange Format ...